M,
To get the Rate we need the wire diameter, the inside diameter, the
number
of active coils (not the total coils).
To get the Load we take the Rate and multiply it by the deflection.
There is no such term as Load Rate, it is the same as Load.
Load is the amount of weight the spring will support at a given
height.
Rate is the amount of weight required to deflect a spring one inch.
If a spring has a 200 Lb Rate and it is deflected 3 inches, then it
has a Load of 600 lbs.
-Mike
|